IT security container with or without fire protection as mobile server room construction
IT-security container is the solution for lack of space in fast growing IT landscapes.
We build you a future-proof, modern data center at an unbeatable cost-benefit ratio.
Advantages of the container:
- safe room construction to protect the hardware against all physical damage
- installation in a warehouse or outdoors
- mobile and movable
- several containers as a row possible
- burglar-proof, fire-fighting waterproof, noise-reducing
- energy-efficient cooling
- hot aisle / cold aisle
- fire protection container with protection from the outside and inside
- protection from debris loads
IT-safety container offers the possibility to be equipped with extensive accessories such as air
conditioning, fire detection, extinguishing systems, UPS, access control and much more. Since
we implement all services ourselves, we deliver the complete turnkey solution from one source
with an unbeatable price.
Benefit from our many years of experience in data center construction. Especially for your needs
we dimension all essential sizes, performances and reserves correctly. We provide an unrivaled
guarantee of many years for the implemented overall solution.
You have one contact person for all your needs.
The effort that arises for you is minimal. You save yourself the time-consuming procedure of
having to take everything into your own hands. You do not have to deal with trades such as
building contractors and craftsmen. You receive the finished container and only install your
servers - done
After completion easy transport
A server room goes on a journey:
- suitable for land and ship loading
- delivery by crane possible
- turnkey delivery plug-and-play
- final assembly on site by our technicians
Customized container sizes
We will build the container in the size that is optimal for you. Below are a few examples:
- 10 feet: 2.4 x 2.4 x 3 m (wxhxl), 7.1 kW cooling capacity, 6 kVA UPS, 2 racks, B1
- 20 feet: 2,4 x 2,4 x 6 m (bxhxl), 6,4 kW cooling capacity,
10 kVA USV, 4 racks, B1 - 19m²: 3,2 x 3 x 6 m (bxhxl), 13,4 kW InRow cooling capacity,
15 kVA USV, 2 racks, EI90 - 23m²: 3,2 x 3 x 7,2 m (bxhxl), 20,3 kW InRow cooling capacity,
20 kVA USV, 5 racks, EI90 - 29m²: 3,2 x 3 x 9 m (bxhxl), 25 kW InRow cooling capacity,
2x15 kVA USV, 8 racks, EI90
Container with fire prevention
Advantages of fire prevention:
- permanent protection in closed rooms by reducing oxygen
- the oxygen content is kept at a fixed level by controlled introduction of nitrogen
- in this atmosphere no fire can develop
- areas protected by fire prevention remain accessible and ensure an unhindered process flow
Further equipment features:
- 19 inch server racks
- air conditioning
- alarm systems
- early fire detection
- extinguishing system or oxygen reduction
- access control
- video surveillance
- electric controls
- power distribution
- UPS
- diesel-aggregates
- and much more
Cold and hot aisle containment
By physically separating the cooling air from the warm exhaust air,
the efficiency of cooling in the data center can be significantly
increased.
Usually cold and warm aisles are additionally insulated by
enclosures to further reduce the mixing of cooling and exhaust
air.