Physical infrastructure for your IT systems
Server room with hot and cold aisle
Your IT systems in good hands
We deliver the secure physical business equipment you need to ensure that your
IT environment works without system failures and all relevant risks are eliminated.
This begins with individual, secured server protection cabinets, the retrofitting of
security components for your existing data center and ends with a complete turnkey
solution as a fail-safe, tested data center.
Secure electrical cabling
Electrical cabling and power distribution for IT
systems according to ÖVE/ÖNORM E 8001.
Secure power with maximum availability is one of
the most important features in an IT server room
or data center.
Together with our UPS systems, we supply the
secure IT power for the highest availability of
your systems. For this purpose, we use pure IT
electrical components in compliance with current
standards and regulations (E 8001 in Austria or IEC
60364 international).
We prepare the legally prescribed system log for
each system and also carry out checks during operation.
Here you can find more information.
Fire protection
Fire fighting from the inside!
For the protection of important company areas,
extinguishing with gases is the optimal solution,
because the introduction of the extinguishing agent itself
does not cause any additional damage.
The extinguishing is completely residue-free, so that technical
equipment remains functional and valuable assets are preserved.
Depending on the size and local conditions, we install various
types of extinguishing systems in compliance with national
regulations (TRVB S152, TRVBS151 and TRVB S123 for Austria
or ISO/VDS for Germany).
Air conditioning technology
The basis for a fail-safe IT system is a controlled and secured room climate
Every server needs an adequately dimensioned air conditioning
system if the data center is to remain highly available. A correct
interaction between air conditioning – ventilation – data rack
design is necessary to provide reasonable cooling. The best way
to achieve this is with an oversized air conditioning system (which
we usually implement redundantly) and partially open server racks.
Since our security cells are dust-tight, it is possible to equip all
server racks with perforated doors or side walls and to ventilate
them via a common air conditioning system. Fans in the data racks
are not necessary.
Alarm system – monitoring system
Depending on the module, the faults are displayed locally on site, via web or SMS.
The following physical disturbances can be monitored, recorded or reported:
- operation/fault messages
- access authorization
- temperature
- air humidity
- water ingress
- smoke development
- vandalism